Science, asked by erolla, 1 month ago

4 The bore and stroke of a double acting pump running at 60 rpm are 0.15 m and 0.3 m respectively. The total head against which works 30 m. If the efficiency is 80% determine the power required. [4050 W]​

Answers

Answered by shubhamugale2005
0

The bore and stroke of a double acting pump running at 60 rpm are 0.15 m and 0.3 m respectively. The total head against which works 30 m. If the efficiency is 80% determine the power required. [4050 W]