5. A hollow cast iron column with fixed ends supports an axial load of 1000 KN. If
the column is 5 m long and has an external diameter of 250 mm, find thickness of
the metal required. Use Ranking-formula_taking a constant of
1/1600 and
assume a working stress of 80 MN/m?
Answers
Answered by
2
Answer: 29.4mm