Environmental Sciences, asked by akhil1248, 11 months ago

A 4 pole, lap wound dc generator has a useful flux of 0.07 webers per pole. Calculate the generate emf when it is rotataed at a speed of 900 RPM with the help of prime mover. Armature consists of 440 no of conductors. Also calculate the generated emf if lap wound armature is replaced by wave woumd armature.

Answers

Answered by pallavdwivedi2
2

Answer:

Very Easy - Lol -

P = 4 Z = 440 Φ = 0.07 Wb and N = 900 r.p.m. is the Answer.

Answered by DiyaTsl
2

Answer:

  • In-lap wound generator  E = 420V
  • In wave wound generator E = 840V

Explanation:

  • Given,

Number of poles of a lap wound D.C generator P =4poles

Useful flux Ф = 0.07Webers/pole

Speed of rotator Z = 900 RPM

Number of conductors N = 400 conductors

For lap winding, the number of parallel paths A = P

we know that,

  • E = Ф (\frac{ZNP}{60A})

where,

E = emf generated

Ф = useful flux

Z = speed of rotator

P = number of poles

N= number of conductors

A = number of parallel paths

Substituting the known values in the  above formula,

E = Ф (\frac{ZNP}{60A})

E = \frac{0.07*900*440 }{60}

E = \frac{25200}{60}\\ \\E = 420V

In the case of lap winding emf generated is  E = 420V.

  • In wave wound armature,

Number of parallel paths A = 2

  • E = Ф (\frac{ZNP}{60A})

       E = \frac{4*0.07*900*440 }{60*2}

E = 840V

Therefore, in the case of wave wound armature generated emf E = 840V.

#SPJ2