Physics, asked by omkapse007, 1 month ago

A maximum pull of 100 kN acts on the
round tie bar of the roof truss. If the safe
tensile and shearing sress in the rod are 80
N/mm2 and 30 N/mm2 respectivly,find the
outside diameter of coupler nut in
turnbuckle.(do -58mm).
54mm (say)
67mm (say)
70mm (say)
74mm (say)​

Answers

Answered by nikhiltaware374
1

Answer:

Explanation:

74