A single phase full wave mid-point SCR converter, uses
a 230/200 V transformer with the centre tap on the
secondary side. The P.I.V, per SCR is
a. 100 V
b. 1411
c. 214V
d. 282V
Answers
Answered by
0
Given:
A single phase full wave mid-point SCR converter, uses a 230/200 V transformer with the centre tap on the secondary side.
To find:
The P.I.V, per SCR is
Solution:
From given, we have,
A single phase full wave mid-point SCR converter, uses a 230/200 V transformer with the centre tap on the secondary side.
Vm = √2 Vs
Substitute the given values in the above equation.
Vm = √2 × 200
continue the further calculation.
Vm = 282.84 V
This value of the voltage can be rounded off to the nearest digit as follows.
Vm = 282
Therefore, the option (d) 282 V is correct.
Similar questions