A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current. If the triggering angle is 30, the input power factor will be
Answers
Answered by
6
a/c to question,
A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current.
The input power factor is given by,
where is the triggering angle .
here it is given that,
so, input power factor = 0.9cos30°
= 0.9 × √3/2
= 0.45 × 1.732 [ as √3 = 1.732 ]
= 0.7794
hence, input power factor will be 0.7794