An electric kettle consumes 1kw of electric power when operated at 220v. a fuse wire of what rating must be used for it
Answers
Answered by
7
Used for it?
1A
2A
4A
5A
-
P = V*I => 1kW = 1000W = 220*i => 1000W/220V = i = 100/22 = 50/11 = 4.55A so the answer is 5A
-
6A
Current consumed is 1000/220 = 4.54A. 133% of that is 6.06
RERATING: For 25ºC ambient temperatures, it is
recommended that fuses be operated at no more than
75% of the nominal current rating
1A
2A
4A
5A
-
P = V*I => 1kW = 1000W = 220*i => 1000W/220V = i = 100/22 = 50/11 = 4.55A so the answer is 5A
-
6A
Current consumed is 1000/220 = 4.54A. 133% of that is 6.06
RERATING: For 25ºC ambient temperatures, it is
recommended that fuses be operated at no more than
75% of the nominal current rating
Answered by
7
Answer:
given:-p = 1 K W which is=1000W
V=220V
Now P=VI
therefore I = P/V
I=1000/220= 4.5A
therefore the rating must be either 4.5A or 5A.