Science, asked by latifahmadkhan18, 7 hours ago

(b) A 10 KVA, 500/100 V transformer has the primary referred parameters are Rieq
ohm, Xieq=5.2 ohm. When supplying power to a lagging load the current, power and
voltage measured on primary side were 20 A, 8 kW and 500 V respectively. Calculate
the voltage on secondary terminals. Also find volta- regulation at power factor of
0.85 lagging.

Answers

Answered by psakhare83
32

Answer:

Rating of transformer =10\: KVA=10*10^{3}\: VA=10KVA=10∗10

3

VA

Power factor on primary side,

cos\: \phi _{1}=\frac{P}{V_{1}I_{1}}=\frac{8*10^{3}}{500*20}=0.8\: kgcosϕ

1

=

V

1

I

1

P

=

500∗20

8∗10

3

=0.8kg

\therefore∴ sin\: \phi _{1}=sin\: cos^{-1}\: 0.8=0.6sinϕ

1

=sincos

−1

0.8=0.6

Primary induced emf, E_{1}=V_{1}-I_{1}R_{ep}\: cos\: \phi _{1}-I_{1}\: X_{ep}\: sin\: \phi _{1}E

1

=V

1

−I

1

R

ep

cosϕ

1

−I

1

X

ep

sinϕ

1

=sin\: 500-20*0.3*0.8-20*5.2*0.6=432.8\: V=sin500−20∗0.3∗0.8−20∗5.2∗0.6=432.8V

Transformation ratio, K=\frac{100}{500}=0.2K=

500

100

=0.2

Secondary induced emf, E_{2}=E_{1}*K=432.8*0.2=86.56\: VE

2

=E

1

∗K=432.8∗0.2=86.56V

Secondary terminal voltage on load,

V_{2}=E_{2}=86.56\: VV

2

=E

2

=86.56V (since all the parameters are referred to primary side)

The equivalent circuit and phasor diagram is shown in Fig. 2.42(b