Science, asked by baburahul9297, 4 months ago

Example 1: A single-phase energy meter has a constant of 6000 rev/kWh. A test was carried
out with a resistive load for one minute, during which the meter made 21 revolutions. The voltage
was 110 volts and current 2 A. Calculate the % error.
De here to search
O
в​

Answers

Answered by ishetashukla2007
0

Answer:

The number of revolutions made by the energy meter per kilowatt-hour is known as the meter constant of an energy meter.

Unit of meter constant is revolution per kilowatt-hour (rev/kWh)

It is constant for a particular energy meter

Answered by javadmkhan111
0

Explanation:

-4.46% ................................... ANS