Example 1: A single-phase energy meter has a constant of 6000 rev/kWh. A test was carried
out with a resistive load for one minute, during which the meter made 21 revolutions. The voltage
was 110 volts and current 2 A. Calculate the % error.
De here to search
O
в
Answers
Answered by
0
Answer:
The number of revolutions made by the energy meter per kilowatt-hour is known as the meter constant of an energy meter.
Unit of meter constant is revolution per kilowatt-hour (rev/kWh)
It is constant for a particular energy meter
Answered by
0
Explanation:
-4.46% ................................... ANS