>>Two devices of rating 22 W; 220 V and 11 W; 220 V are connected in series. The combination is connected across 440 V mains. The fuse of which of the two devices is likely to burn when the switch is on? Justify your name!
FASTEST ANSWER WILL BE MARKED AS BRAINLIEST!
Answers
Answered by
3
Answer:
✍️The fuse of device of rating 11W; 220V will burn.
________________
∴ Resistance of 11W device will be two times then that of the device of 44w.
∴ Voltage across 11W = I × R = 0.8× 4400= 352 V
∴ Voltage across 22W = I × R = 0.8× 2200 = 176 V
352V across the device of 11W ; 220V rating is sufficient to burn.
✍️ THEREFORE, The fuse of device of rating 11W; 220V will burn.
______________________
Answered by
1
Answer:
The switch of both devices will burn as they have a voltage of 220 V and the voltage connected to the mains is 440 V ;
And also, they both are connected in series,
So, Both will burn.
Hope it helps u !!!!!!!
Please mark my answer as the BRAINLIEST.
By - Rishi Bhardwaj