>>Two devices of rating 22 W; 220 V and 11 W; 220 V are connected in series. The combination is connected across 440 V mains. The fuse of which of the two devices is likely to burn when the switch is on? Justify your name!


FASTEST ANSWER WILL BE MARKED AS BRAINLIEST!

Answers

Answered by Anonymous
3

Answer:

 \tt  \red{ANSWER}

✍️The fuse of device of rating 11W; 220V will burn.

________________

R = \frac{ { V}^{2} }{W}  \\

Resistance  \:  \: of  \:  \: 11 W \:  \:  device  =  \frac{( {220}^{2}) }{11}  = 4400

Resistance  \:  \: of  \:  \: 22 W \:  \:  device =  \frac{( {220}^{2}) }{22}  = 2200

∴ Resistance of 11W device will be two times then that of the device of 44w.

I =  \frac{V}{R} =  \frac{440}{5500}  = 0.08  \\

∴ Voltage across 11W = I × R = 0.8× 4400= 352 V

∴ Voltage across 22W = I × R = 0.8× 2200 = 176 V

352V across the device of 11W ; 220V rating is sufficient to burn.

✍️ THEREFORE, The fuse of device of rating 11W; 220V will burn.