How the strength of stray field can be measured of permalloy microstructure?
Answers
Answered by
11
We have measured the stray fields of thin permalloy ( Ni <sub>83</sub> Fe <sub>17</sub>) microstructures with different geometries and several thicknesses by magnetic-force microscopy (MFM). The MFM images are compared to corresponding images calculated from micromagnetic simulations. In particular, the type of 180° domain walls is discussed. We observe a transition from cross-tie to asymmetric Bloch walls between 70 and 100 nm film thickness. Good agreement between measurement and simulation is obtained. © 2004 American Institute of Physics.