Slenderness ratio of a 5 m long column hinged at both ends and having a circular cross section with diameter 16 cm is
Answers
Answered by
3
Answer:
125
Step-by-step explanation:
Given Slenderness ratio of a 5 m long column hinged at both ends and having a circular cross section with diameter 16 cm is
5 m = 500 cm
Given λ = I eff / r min
= 500 / r min
I min = Ar^2 min
r min = √ I / A
= √ π (16)^4 x 4 / 64 x π(16)^2
So r min = 4
Now λ = 500 / 4 = 125