The COP of a heat pump is 5 and the power required to drive it is 35 kW. (a) Evaluate the heat transfers from and to the working fluid
Answers
Answered by
1
Answer:Given
Cop=5
Driving power/ work input=35kw
Cop of heat pump= heat rejected to higher temperature reservoir (Q1)/work input
5= Q1/35kw
Q1= 175KW
THEREFORE heat transferred from system is 175KJ/s
Q1=Q2+W Q2= heat taken from lower temperature reservoir
175-35=Q2
Q2= 140 KJ/s
Heat transferred to fluid is 140 kj/s
Explanation:
Similar questions
Chemistry,
12 days ago
History,
12 days ago
Computer Science,
12 days ago
English,
26 days ago
Social Sciences,
26 days ago
Chemistry,
8 months ago
English,
8 months ago
Math,
8 months ago