The external treatment of boiler water feed done by
Answers
Answered by
2
Answer:
Sodium silicate is used to react selectively with magnesium hardness. Calcium bicarbonate entering with the feed water is broken down at boiler temperatures or reacts with caustic soda to form calcium carbonate. Since calcium carbonate is relatively insoluble it tends to come out of solution.
Answered by
0
Answer:
There are many types of external treatment (softening, evaporation, deaeration, membrane contractors etc.) which can be used to tailor make feed-water for a particular system. Internal treatment is the conditioning of impurities within the boiler system.