Physics, asked by d7825apatel, 3 months ago

What is difference between Watt and Volt?
Which is bigger watt or volt?

Answers

Answered by ZalimGudiya
2

Answer:

Watts refer to “real power,” while volt-amperes refer to “apparent power.” Both are simply the product of voltage (V) multiplied by amperage (A). Thus, a device drawing 3 amps at 120 volts would be rated at 360 watts or 360 volt-amperes.

Explanation:

One of the major difference between volts and watts is that the volt is the SI unit of potential difference and electromotive force, whereas the watt measures the SI unit of power. ... The measurement taken in volts is easier as compared to watts because watts is the product of the two quantity i.e., voltage and current.

Answered by kajalmodak970
1

Answer:

watt is bigger

Explanation:

Uninterruptible Power Supply System (UPS) packs up to 3.0 KVA into only 2U of rack space, the EATON 9130 Rackmount UPS delivers superior online power quality and scalable battery runtimes for rack servers, voice and data networks, storage systems, and other IT equipment that require the protection of an uninterruptible power supply. Tower models are also available. Proprietary ABM technology significantly extends battery life while an efficiency rating of >95% reduces your energy costs. Ergonomically designed bright LCD user interface simplifies operation and monitoring

Features & Benefits For EATON 9130 Uninterruptible Power Supply System (UPS)

Eaton 9130 UPS Sizes: 500VA, 750VA, 800VA, 1000VA, 1500VA, 2000VA and 3000VA Rack and Tower UPS:

High Efficiency mode with >95% efficiency rating reduces energy usage and costs

2U form factor, 4-post rail kit, and internal batteries save rack space

Higher wattage with a 0.9 power factor protects more equipment and allows for expanding IT systems

Ergonomically-designed and intuitive LCD user interface and intuitive power-management software simplify the monitoring of your commercial UPS system or industrial UPS system.

Available remote monitoring and management with optional eNotify Remote Monitoring service

Proprietary ABM battery-charging technology and hot-swappable batteries increase battery service life of EATON 9130 UPS (Uninterruptible Power Supply) and system uptime

Product Snapshot

EATON 9130 UPS

Power Rating 700-3000 VA

Voltage 120 Vac, 208-240V

Frequency 50/60Hz (auto-sensing)

Configuration Rackmount or tower

Product Series Powerware

Technical Specifications

9310 TECHNICAL SPECIFICATIONS

GENERAL

User interface Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish

LEDs Four status-indicating LEDs

Topology True online, double-conversion

Diagnostics Full system self-test

UPS bypass Automatic bypass

Dimensions >> Contact an N1C representative for more information <<

Rail kit Included with all rackmount units

ELECTRICAL INPUT

Nominal Voltage 120V: 208–240V

Input Voltage Range 120V: 90–138 Vac (with load PF of 0.7) 208/230V: 160–276 Vac (with load PF of 0.7)

Power draw of UPS 700: 5.8A @120V, 3.4A @208V, 3.0A @230V 1000: 8.3A @120V, 4.8A @208V, 4.3A @230V 1500: 12.5A @120V, 7.2A @208V, 6.5A @230V 2000: 16.6A @120V, 9.6A @208V, 8.7A @230V 2500: 20.8A @120V, 12.0A @208V, 10.9A @230V 3000: 25.0A @120V, 14.4A @208V, 13.0A @230V

Dedicated circuit breaker rating 120V: 700–1500 VA: 15A 2000 VA: 20A 2500–3000 VA: 30A 208/230V: 700–2000 VA: 10A 3000 VA: 16A

Frequency 50/60 Hz

Frequency range 45–65 Hz

ELECTRICAL OUTPUT

Power factor 0.9

On utility voltage regulation ±3% of nominal

On battery voltage regulation ±3% of nominal

Efficiency >95% in high-efficiency mode; >86% in online mode

Frequency regulation ±3% Hz online

Load crest factor 3 to 1

BATTERY

Battery Type VRLA 12V/9 Ah (both internal and external)

Battery Runtime >3 minutes with internal batteries @100% load (0.7 PF)

Battery Replacement Hot-swappable internal and external batteries

Start-on-battery Allows start of UPS without utility input

COMMUNICATIONS

Serial port RS-232 standard, for interface to power management software

USB port HID standard, for communicating with Windows 98 and ME computers

Relay output Common alarm standard

Communications slot Optional communication slots (BD Slot)

Optional communication cards SNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems

1. Due to continuous product improvements, program specifications are subject to change without notice.

Open PDF For More Specs

INDUSTRIES & APPLICATIONS

The EATON 9130 is an ideal battery backup power supply for one- or two-rack users in clinics & hospitals, financial institutions, businesses, and other sites in need of a commercial UPS system that offers superior online power quality and scalable battery runtimes in applications including but not limited to:

smaller data centers, IT systems, or telecom closets

Network switching & processing equipment

PLC controls

High-quality power backup system for AS-400 systems

hope this helps you

please mark this as a brainlest answer please