Which of the following pairs are correctly matched ?1. Standard penetration test....Relative density2. Vane shear....Cohesion3. Consolidation test....Bearing capacitySelect the correct answer using the codes given below :

A. 1, 2 and 3 B. 1 alone C. 1 and 2 D. 2 and 3

Answers

Answered by nandhinimouli
0
ANSWER : (C) 1 and 2



Standard penetration Test (SPT)
is for the test is to provide an indication of the relative density of granular deposits, such as sands and gravels

Vane Shear is to find shear strength of cohesive soils soil specimen.

Cone Penetration Test (CPT) is mainly determined the soil geotechnical property of bearing capacity 

Consolidation Test is conducted to determine the settlement due to primary consolidation. To determine :Rate of consolidation under normal load.Degree of consolidation at any time.      iii.            Pressure-void ratio relationship.Coefficient of consolidation at various pressures.Compression index.  From the above information it will be possible for us to predict the time rate and extent of settlement of structures founded on fine-grained soils. It is also helpful in analyzing the stress history of soil. Since the settlement analysis of the foundation depends mainly on the values determined by the test, this test is very important for foundation design.