Why there is more heat transfer at 120 degree angle?

Answers

Answered by Anonymous
2

Answer:

Step-by-step explanation:

Abstract

The  experimental  investigation  of  the  air  side  heat  transfer  and  pressure  drop  characteristics  at  steady  state  for  the  cross  flow  heat  exchangers  having  flat  tube  configuration  with  staggered  arrangement  are  presented.  The  effect  of  attack angles on the air side is major to study. In addition, the effect of tubes aspect ratios was also studied. Nineteen heat  exchangers  with  four  aspect  ratios  (0.18,  0.39,  0.66  and  1)  and  six  attack  angles  (0,  30,  60,  90,  120  and  150)  are  investigated.  The  water  temperature  of  75  °C  and  the  air  at  ambient  condition  flowed  through  the  heat  exchangers  with  velocity  range  from  2  to  6  m/s.  The  results  show  that  the  thermal  and  the  pressure  drop  characteristics had governed by the attack angles and the tube aspect ratios. For all values of the air velocity of each tube  aspect  ratios,  to  increasing  the  attack  angles  (0  90)  the  heat  transfer  rate  and  the  pressure  drop  were  increased, while the thermal hydraulic performance was decreased. When considered effect of tubes aspect ratios on thermal and pressure drop characteristics, the results indicated that to change of the attack angles of lower tube aspect ratios had effected on thermal and pressure drop more than attack angle changed of higher tube aspect ratios