A galvanometer with a scale divided into 100 equal divisions has a current sensitivity of 10 divisions per
mA and a voltage sensitivity of 2 divisions per mV. What
adoptions are required to read (i) 5 A for full scale and
(ii) 1 division per volt ?
Answers
Answered by
2
Answer:
I
g
=(
10div
1mA
)(100div)=10mA
V
g
=(
2div
1mV
)(100div)=50mV
G=
I
g
V
g
=
10
50
=5Ω
I(current to be measured):-5A
n=
I
s
I
=
10mA
5A
=500
∴s=
n−1
G
=
500−1
5
=1×10
−2
Ω