Physics, asked by ymondal390, 4 months ago

calculate the Apparent power of a star connection 3 phase load if it is connected across the three phase 415 volt 50 HZ supply at the 0.8 power factor and the phase current 10Amps​

Answers

Answered by ksuraj20363
3

Answer:

Y connection, voltage applied across each impedance = 400/√3 so phase current = V/Z=400/10√3= 40/√3 amps

Power in each phase = Phase voltage x phase current = 400/√3 x 40/√3 = 1600/3 VA

Total power(three phases) = 1600/3 × 3 =1600 VA or 1.6 kVA

Active power can be calculated if load angle of 10 ohm impedance is known.