Physics, asked by prithivraj0120, 9 months ago

explain scan A scan B scan and c techiques in details​

Answers

Answered by vivekananda58
2

Answer:

In the Ultrasonic scanning methods, the principle, construction and working is the same as that of the Ultrasonic law detector. Here, it is based on the position o the transducer and the output displayed in the CRO screen, we can classiy the scanning methods into three types

a. A-scan

b. B-scan

c. T-M scan or C-scan

All these three modes of scanning are obtained with respect to the pulses of Ultrasound transmitted into and received from the specimen. The three modes are explained below.

a A-Scan or Amplitude mode display

Amplitude mode display gives only one-dimensional information about the given specimen. In this, a single transducer is used to transmit and receive the pulses from the specimen.

The received or the reflected echo signals from the specimen is given to the Y-Plate and time base is connected to the X-Plate of the CRO, so that they are displayed as vertical spikes along horizontal base line as shown in the figure 1.10.1.

The height of the vertical spikes corresponds to the strength of the echo from the specimen. The position of the vertical spike from left to right along the X-axis corresponds to the depth of penetration.i.e, it gives the total time taken by the Ultrasonic sound to travel from transmitter to the specimen and from the specimen to the receiver.

Thus by passing Ultrasonic waves o known velocity and by noting the time delay, we can find the distance at which the detect or flaws are present, by using the formula.

Distance = Velocity x time

In ultrasonic flaw detector, A-scan method is used to detect the position and size of the flaws.

b. B-Scan or Brightness Mode Scan

B-scan or Brightness mode display gives a two dimensional image. The principle of the B-Scan is same as that of A-Scan except with a small difference. Here in the B-Scan the transducer can be moved rather than keeping in a fixed position. As a result each echo’s are displayed as dots on the screen as shown in the figure 1.10.2.

c. T.M Scan or Time –Motion Mode or C-Scan display

This method is used to obtain the information about the moving object.

This combines the features of both A-Scan as well as B-Scan. In this the transducer is held stationary as in A-scan and echoes appear as dots in the B-scan.