Evaluation of newer methods and optimization of existing methods for the susceptibility testing of second-line drugs, especially ethionamide, are essential when treatment of multidrug-resistant tuberculosis (MDR-TB) is warranted. The ideal method must clearly demarcate sensitive from resistant strains. Hence, optimization of the conventional minimum inhibitory concentration (MIC) method was attempted using diluted inoculum. The optimized MIC method was evaluated using 206 Mycobacterium tuberculosis strains isolated from new and previously treated tuberculosis patients and were compared with the conventional MIC method and proportion sensitivity (PST) method. The sensitivity and specificity of the optimized MIC method in comparison with the PST method was 74% and 90%. Assessment of the optimized MIC method with the conventional MIC method gave a sensitivity of and specificity of 73% and 98%. Overall agreement between the methods was found to be.
Endowed with the ability to identify the resistant strains precisely, the optimized MIC method can be used for screening resistance to ethionamide.
hope help u!!
_______
Evaluation of newer methods and optimization of existing methods for the susceptibility testing of second-line drugs, especially ethionamide, are essential when treatment of multidrug-resistant tuberculosis (MDR-TB) is warranted. The ideal method must clearly demarcate sensitive from resistant strains. Hence, optimization of the conventional minimum inhibitory concentration (MIC) method was attempted using diluted inoculum. The optimized MIC method was evaluated using 206 Mycobacterium tuberculosis strains isolated from new and previously treated tuberculosis patients and were compared with the conventional MIC method and proportion sensitivity (PST) method. The sensitivity and specificity of the optimized MIC method in comparison with the PST method was 74% and 90%. Assessment of the optimized MIC method with the conventional MIC method gave a sensitivity of and specificity of 73% and 98%. Overall agreement between the methods was found to be.
Endowed with the ability to identify the resistant strains precisely, the optimized MIC method can be used for screening resistance to ethionamide.
hope help u!!
Answered by
0
hye!
___
↪Avium isolates were tested to determine the MICs of ethambutol by REMA and agar dilution method.
↪MTB isolates were also tested by the LJ proportion method.
↪REMA provided ethambutol susceptibility results for all the isolates within 8 to 9 days.