What is the system reliability when two components having reliability of 80% and 90% are combined in parallel?
Answers
Answered by
0
Answer:
good care distinct app very adjustable adjust track
Answered by
0
The system reliability is 0.98.
For parallel system reliability can be calculated by the formula -
R=1-(1-R1)(1-R2)......
For given question -
R1= 80%
R1= 0.8
R2= 90%
R2= 0.9
Putting the values in equation -
R= 1-(1-0.8)(1-0.9)
R= 1-0.02
R= 0.98