81

The efficiency at full load and half loads are 97% and 96.4% respectively.

Given

Apparent power of the transformer = 25000 VA

power factor = 1

=> real power = Apparent power x power factor

= 25000 watts

At full load

Net input = 25000 w

iron loss = 350 w

copper loss = 400 w

=> net loss = 350 + 400 = 750 w

=> output = 25000 - 750 = 24250 w

=> efficiency = output/input = 24250/25000 = 0.97 = 97%

At half load

Net input = 25000/2 = 12500 w

iron loss = 350 w

copper loss = 400/4 = 100 w

=> net loss = 350 + 100 = 450 w

=> output = 12500 - 450 = 12050 w

=> efficiency = output/input = 12050/12500 = 0.964 = 96.4%