Physics, asked by PoojaDas514, 1 year ago

Consider the following statements:

Bearing stiffness, in plate girders, are:
1. provided at supports.
2. provided under concentrated loads.
3. provided alternately on the web.

Which of the statements given above is/are correct ?

Answers

Answered by kvnmurty
0
All the statements are true.

 bearing stiffeners are provided on the web plates, under the concentrated loads, and at supports  - all to prevent buckling or bending or shearing stress..


Answered by nandhinimouli
0
Stiffeners are provided to transfer transverse concentrated compressive force on the flange into the web and are essential for desired performance of web panels. These are referred to as bearing stiffeners.

(1) is true.It is provided to support

(2) is true.Bearing stiffeners are required whenever concentrated loads, which could cause vertical buckling of web of the girder, are applied to either flange.

(3) is partially true. If the check indicates that the web may fail in bearing,then a bearing stiffener must be provided.The stiffener should be checked to ensure that it can carry the applied load less the capacity of the unstiffened web ( But this check is required only for intermediate stiffeners )