Physics, asked by GargiP8618, 8 months ago

Find the thickness of a five rupee coin with the screw gauge, if the pitch scale reading is 1 mm and its head scale coincidence is 88.

Answers

Answered by prakhargupta3301
1

Answer:

1.88mm

Explanation:

Assuming there are 100 marks per pitch, then LC will be

=1mm/100=.01mm

Reading in screw gauge:

MSR+ conincidence*LC

1mm + (88 x .01)mm

(1+ 0.88) mm

1.88 mm

Similar questions